Overview

Overview

The FiberPlex Technologies RMC-3700 is a heavy duty enclosure designed to survive in indoor and outdoor environments. The chassis is rated to IP-54, protecting the internal components from dust and windblown rain. Each chassis provides up to nine (9) available slots for any FiberPlex fiber optic isolator (FOI) or telephone disconnect unit.

RMC-3700_600.gifThe tenth available slot must be occupied by a power supply module. Each chassis will be shipped with one power supply module (PSM). A second power supply module may also be added for system power redundancy, leaving eight (8) available slots for the installation various combinations of FOI units. If the first power supply module fails, the second will assume the entire system load and carry on normally. The failed power supply module may be hot swapped with a new one without interruption of FOI operation.

Each FOI must be mated to a 3000-series chassis mount adapter (CMA), which interfaces the FOI with the slot and assures correct alignment of the isolator power connector and the chassis power bus.

Typical Applications

The RMC-3700 can be punched to accommodate conduit per the clients’ needs. The heavy mounting ears allow solid mounting on any vertical surface. An integrated door hasp allows for locking the chassis.  This makes the RMC-3700 perfect for outdoor SCADA applications, perimeter security for campus’ and military bases, rooftop mounting for antenna or SATCOM applications or even along rail or roadways for transportation data and control.

Additional information

Weight 5.00 lbs
Dimensions 5.00 × 5.00 × 5.00 in

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Features

Features:

  • Holds up to 9 FOI modules
  • IP-54 Rated
  • One PSM-3010 power supply included
  • Power redundancy is available through an optional second power supply module.
  • Active cooling for FOI modules
  • Specialty louvered vents and sealed door resist ingress of heavy and windblown rain.
  • Conduit holes may be punched into chassis in of customer’s choice.

Applications:

  • Campus
  • Bases
  • Physical Security
  • Rooftop Applications
  • SCADA
  • Transportation

Specifications

FAN SPECIFICATIONS

 

Min

Typ

Max

Unit

Fan Speed

2500

RPM

Air Pressure

3.5

mmH2O

0.14

inH2O

Air Flow

50.5

CFM

1.43

m3/min

Noise

34

dBA @ 1m

PHYSICAL SPECIFICATIONS

Case Dimensions

Depth

Width

Height

Weight

RMC-3700

7.38 in (187.5 mm)

26.25 in (667 mm)

16.0 in (406 mm)

64 lb (29 kg)

PSM-3010 Specifications

ELECTRICAL SPECIFICATIONS

 

Min

Typ

Max

Unit

Input

 

Voltage

100

240

VAC

Frequency

50

60

Hz

Power

125

W

Output

Voltage

9

VDC

Supply Current

8.3

A

Power

76.5

W

ENVIRONMENTAL SPECIFICATIONS

 

Min

Typ

Max

Unit

Storage Temperature

-40

85

°C

Operating Temperature

0

50

°C

PHYSICAL SPECIFICATIONS

Case Dimensions

Length

Width

Height

Weight

PSM-3010

9.56 in (243 mm)

1.57 in (40 mm)

3.49 in (88 mm)

1.6 lb (0.7 kg)

Ordering Information

 


RMC-3700